Racing Pigeon

The following database tables have been arranged in three categories: Measurands, Clinical Applications and Laboratory Applications. 

Measurands

› Biochemistry (1 table)

Clinical Applications:

Focuses on clinically related aspects of biological variation (reference change values).

Laboratory Applications:

Focuses on laboratory related aspects of biological variation (quality standards).

Reference number relates to the citation list.

Legend:

CVI - intraindividual variation.

CVG- between individual variation.

CVA - analyser variation (reported in the study, shown in red if > 0.5 x CVI). This can be determined by replicate analyses or from quality control studies (QCM)

II - Index of Individuality. A high level indicates subject-based reference intervals (RCV) are more appropriate, a low level indicates population-based reference intervals are appropriate, intermediate levels indicate both reference change values and reference intervals should be assessed.

RCV - reference change value calculated to 95% and 99%.

These terms are explained on the ‘About BV’ page.

Biochemistry

MeasurandSample TypeReferenceHealth StatusBreed(s)Subjects (n)
Samples
Frequency
CVI (%)CVG (%) CVA (%)

Source
II

Category
RCV (95%)

RCV (99%)
Comments
Aspartate aminotransferase (AST)Plasma (heparin)17healthyColumba livia1618.027.32.21.5150.23ALCYON 300 i analyzer, not in duplicate (small volume sample in small species),
NOT ANOVA, short frequency may introduce autocorrelation errors. Distributions not noted.
15QCMIntermediate66.19
3-4 day
Creatine kinase (CK)Plasma (heparin)17healthyColumba livia1643.363.41.41.46120.0ALCYON 300 i analyzer, not in duplicate (small volume sample in small species),
NOT ANOVA, short frequency may introduce autocorrelation errors. Distributions not noted.
15QCMIntermediate158.13
3-4 day
GlucosePlasma (heparin)17healthyColumba livia168.49.51.11.1223.5ALCYON 300 i analyzer, not in duplicate (small volume sample in small species),
NOT ANOVA, short frequency may introduce autocorrelation errors. Distributions not noted.
15QCMIntermediate30.92
3-4 day
Lactate dehydrogenase (LDH)Plasma (heparin)17healthyColumba livia16102.1119.32.21.2282.9ALCYON 300 i analyzer, not in duplicate (small volume sample in small species),
NOT ANOVA, short frequency may introduce autocorrelation errors. Distributions not noted.
15QCMIntermediate372.75
3-4 day
Total proteinPlasma (heparin)17healthyColumba livia167.514.60.01.9520.78ALCYON 300 i analyzer, not in duplicate (small volume sample in small species),
NOT ANOVA, short frequency may introduce autocorrelation errors. Distributions not noted.
15QCMHigh27.38
3-4 day
Uric AcidPlasma (heparin)17healthyColumba livia1631.139.51.61.386.26ALCYON 300 i analyzer, not in duplicate (small volume sample in small species),
NOT ANOVA, short frequency may introduce autocorrelation errors. Distributions not noted.
15QCMIntermediate113.67
3-4 day